Roll over image to zoom in
Fluke 725/P27EX
$2,917.00
Introducing the Fluke 725/P27EX, the ultimate solution for hazardous environments. With its intrinsically safe design, this pressure calibrator meets the most stringent safety standards, ensuring your peace of mind in explosive atmospheres. Its rugged construction and intuitive interface make it easy to use, even in the most challenging conditions. Experience unparalleled accuracy and reliability with the Fluke 725/P27EX, the industry-leading choice for hazardous area pressure calibration.
- Fluke Model 725
- Measure volts, mA, RTDs, thermocouples, frequency, and ohms
- Source/simulate volts, mA, RTDs, thermocouples, frequency, and ohms
- Measure and source pressure using Fluke 700P series pressure modules
- Dual display shows input and output
- Built in 24V loop power supply
- Programmable step and ramp for automated testing
- Powered by 4 AA batteries (25 hours typical operation)
- Size/weight 7.9 x 3.8 x 1.9
>
Each Unit Includes
- 300 PSI Pressure Module
- TL75 Test Leads
- AC70 Test Clips
- One pair of stackable test leads
- Product Overview Manual
- Users Manual
- CD-Rom
- 3 Year Warranty
- CE and CSA markings
>
Measurement Accuracy | ||
Voltage DC | 30.000 V | 0.02% 2 counts (upper display) |
30.000 V | 0.02% 2 counts (lower display) | |
100.00 mV | 0.02% 2 counts | |
-10.00 mV to 75.00 mV | 0.025% 1 count (via TC connector) | |
Current DC | 24.000 mA | 0.02% 2 counts |
Resistance | 0.0 to 400.0 Ω | 0.1 Ω (4-wire), 0.15 Ω (2- and 3-wire) |
401 to 1500 Ω | 0.5 Ω (4-wire), 1 Ω (2- and 3-wire) | |
1500 to 3200 Ω | 1 Ω (4-wire), 1.5 Ω (2- and 3-wire) | |
Frequency | 2.0 to 1000.0 CPM | 0.05% 1 count |
1.0 to 1100.0 Hz | 0.05% 1 count | |
1.00 to 10.00 kHz | 0.05% 1 count | |
Sensitivity | 1 V peak-to-peak-minimum | |
Pressure | Accuracy from 0.025% of range using any of 29 pressure modules (for detailed specifications refer to pressure modules in options and accessories). Modules available for differential, gauge, vacuum, absolute, dual and high pressure. | |
Source Accuracy | ||
Voltage DC | 100.00 mV | 0.02% 2 counts |
10.000 V | 0.02% 2 counts | |
-10.00 mV to 75.00 mV | 0.025% 1 count (via TC connector) | |
Current DC | 24.000 mA (source) | 0.02% 2 counts |
24.000 mA (simulate) | 0.02% 2 counts | |
Resistance | 15.0 to 400.0 Ω | 0.15 Ω (exc. current 0.15 to 0.5 mA), 0.1 Ω (exc. current 0.5 to 2 mA) |
401 to 1500 Ω | 0.5 Ω (excitation current 0.05 to 0.8 mA) | |
1500 to 3200 Ω | 1 Ω (excitation current 0.05 to 0.4 mA) | |
Frequency | 2.0 to 1000.0 CPM | 0.05% |
1.0 to 1100.0 Hz | 0.05% | |
1.00 to 10.00 kHz | 0.25% | |
Waveform | 5 V p-p squarewave, -0.1 V offset | |
RTDs and Thermocouples | ||
Measure accuracy | NI-120 | 0.2°C |
PT-100 (385) | 0.33°C | |
PT-100 (393) | 0.3°C | |
PT-100 (JIS) | 0.3°C | |
PT-200 (385) | 0.2°C | |
PT-500 (385) | 0.3°C | |
PT-1000 (385) | 0.2°C | |
Resolution | 0.1°C | |
J | 0.7°C | |
K | 0.8°C | |
T | 0.8°C | |
E | 0.7°C | |
R | 1.8°C | |
S | 1.5°C | |
B | 1.4°C | |
L | 0.7°C | |
U | 0.75°C | |
N | 0.9°C | |
Resolution | J, K, T, E, L, N, U: 0.1°C, 0.1°F B, R, S: 1°C, 1°F | |
XK | 0.6°C | |
BP | 1.2°C | |
Source accuracy | NI-120 | 0.2°C |
PT-100 (385) | 0.33°C | |
PT-100 (393) | 0.3°C | |
PT-100 (JIS) | 0.3°C | |
PT-200 (385) | 0.2°C | |
PT-500 (385) | 0.3°C | |
PT-1000 (385) | 0.2°C | |
Resolution | 0.1°C | |
Accuracy stated for 4-wire measurement. | ||
J | 0.7°C | |
K | 0.8°C | |
T | 0.8°C | |
E | 0.7°C | |
R | 1.4°C | |
S | 1.5°C | |
B | 1.4°C | |
L | 0.7°C | |
U | 0.75°C | |
N | 0.9°C | |
Resolution | J, K, T, E, L, N, U: 0.1°C, B, R, S: 1°C | |
XK | 0.6°C | |
BP | 1.2°C | |
Specifications | ||
Ramp functions | Source functions | Voltage, current, resistance, frequency, temperature |
Ramps | Slow ramp, Fast ramp, 25% step-ramp | |
Loop power function | Voltage | 24 V |
Accuracy | 10% | |
Maximum current | 22 mA, short circuit protected | |
Step functions | Source functions | Voltage, current, resistance, frequency, temperature |
Steps | 25% of range, 100% of range | |
Environmental Specifications | ||
Operating temperature | -10°C to 55°C | |
Storage temperature | -20°C to 71°C | |
Operating altitude | 3000 m | |
Safety Specifications | ||
Agency approvals | EN 61010-1:1993, ANSI/ISA S82.01-1994, CAN/CSA C22.2 No 1010.1:1992 | |
Mechanical and General Specifications | ||
Size | 130 x 236 x 61 mm | |
Weight | 0.65 kg | |
Batteries | 4 AA alkaline batteries | |
Battery replacement | Separate battery compartment, accessable without breaking calibration seal | |
Side port connections | Pressure module connector, also used for remote real-time programming |